Is your walk-in on R-404A or R-22? Repair, retrofit or replace

If your walk-in cooler or freezer has some years on it, it may run on R-404A, or on R-22 if it's older still. Both can still be repaired. But the rules around these refrigerants have changed, so the next big repair is a good time to ask a bigger question. Do you fix it, switch it to a newer refrigerant, or replace it?

Not sure which refrigerant you have? Look for the nameplate on the outdoor or condensing unit. It usually lists the refrigerant type.

Why older refrigerants are getting harder to buy

R-22. Since January 1, 2020, EPA has not allowed R-22 to be produced in or imported into the U.S. It can still be used to service existing equipment, but no new supply is being made. Repairs have to draw on refrigerant that's already out there.

R-404A. R-404A is an HFC refrigerant. Under a federal law called the AIM Act, EPA is phasing down how much HFC gets produced and imported. EPA also caps the global warming potential (GWP) of the refrigerant allowed in many new systems. For new systems EPA classes as retail food refrigeration with a remote condensing unit, the limit is 1,400 for installs starting July 27, 2026, dropping to 150 or 300 on January 1, 2032. Which rules apply depends on the system, so ask us about yours. EPA's GreenChill program lists R-404A at 3,922 on that same scale.

What those limits don't do is shut down your current walk-in. They apply to new installations. EPA says parts used to fix an existing system fall outside them. A working R-404A walk-in can be repaired.

The catch is supply. As old refrigerants get harder to come by, prices tend to rise, and that adds up fastest on a system that leaks.

Option 1: Repair and keep your refrigerant

This usually fits when the system is in good shape overall and the problem is one part, like a fan motor, a control or a valve. You fix the part and keep running.

Watch for leaks. If you're recharging the system every season, you keep buying a refrigerant that's getting scarcer. Fix the leak first. And if a compressor has already been replaced once and failed again, read why a walk-in compressor keeps failing before you put in another one.

Option 2: Retrofit to a newer refrigerant

A retrofit keeps your box, coils, compressor and most of the piping, and changes the system over to a newer blend such as R-448A, R-449A, R-407A or R-407F. Done right, it's more than swapping one refrigerant for another:

  • Temperature glide. Newer blends boil over a range of about 10°F instead of at one point. The tech has to set the valves from the right reading, or liquid can wash back to the compressor.
  • Expansion valves. These feed refrigerant into the coil. Valves from an R-404A system are often too big for the new blend and tuned to R-404A's higher pressures, so they're often replaced. Valves from an R-22 system are a closer match and often stay. Either way, they get checked and adjusted after startup.
  • Other valves. A liquid line solenoid valve sized for R-404A may be too big to shut off reliably with the new blend. Most other valves carry over. All of them get checked.
  • Oil. R-22 systems usually run mineral oil, and the new blends need a synthetic oil called POE. Getting the old oil out can take several oil changes. R-404A systems already use POE, though fresh oil is still a good idea.
  • Filter-driers. These catch moisture and dirt, and all of them get replaced. On an R-22 system the new oil can knock old deposits loose, so the driers get checked again over the first day and changed until the system is dry.
  • Seals and leaks. Old gaskets and O-rings, especially in R-22 systems, tend to leak after the changeover. Replacing them is the safer move, and the system gets leak checked.
  • Capacity. Each blend moves a different amount of refrigerant for the same cooling, so parts sized for the old one may not fit. Afterward, a tech should confirm the box cools down and holds temperature.
  • Labeling. The unit should be labeled with the new refrigerant and oil, so the next tech knows what's in it.
Illustrative graphic comparing three paths for a walk-in on R-404A or R-22. 
               Repair: keep the refrigerant you have; fits when one part failed and there are no repeat leaks; 
               the older refrigerant can get harder to find and cost more, and EPA limits on new systems don't cover repairs. 
               Retrofit: change to a newer blend; coming from R-404A new expansion valves are often needed, 
               coming from R-22 mineral oil is changed to POE oil, filter-driers and seals are replaced, 
               the system is leak checked, superheat is set from the dew point and the unit is labeled. 
               Replace: install a new system; fits when the compressor or coils are worn out, leaks keep coming back 
               or too many parts would need changing; new systems may fall under EPA refrigerant limits, so ask about yours. 
               A bar explains glide: at one pressure the newer blends start boiling at the bubble point and finish about 
               10 degrees F warmer at the dew point, while R-404A spreads about 1 degree F.
Illustrative graphic, not to scale.

Rule of thumb: an R-22 system often keeps its valves but usually needs the oil change. An R-404A system keeps its oil type but often needs new expansion valves.

Option 3: Replace the system

Replacing tends to make more sense when the compressor is worn out, the coils are in bad shape, leaks keep coming back, or a retrofit would mean changing so many parts that you're close to a new system anyway. A new system may fall under EPA refrigerant limits that depend on its type and install date, so the refrigerant choice is part of the plan. See our commercial refrigeration installation page for what that involves.

Before you decide

Not every problem on an older walk-in is about refrigerant. A box that runs warm only in cold weather may have a head pressure problem, and one that never shuts off may have a valve feed problem. Find the real cause before choosing a path.

A technician can check the refrigerant type, look for leaks, test the compressor, and look at the oil, the valves and how well the box holds temperature. Then you can weigh all three options with real information. We repair and install walk-in coolers, freezers and commercial refrigeration systems, and we're EPA 608 Certified. Servicing a 60-mile radius of Knoxville, TN. Our office hours are Monday to Friday, 7 AM to 5 PM Eastern, and emergency service is available after hours. Learn more about our walk-in cooler and freezer repair.

FAQs

Is R-404A banned?

Not for the system you already have. EPA's limits apply to new installations, and parts used to fix an existing system fall outside them. An existing R-404A walk-in can still be serviced.

Can a tech just add a newer refrigerant to my old system?

No. A retrofit is a planned changeover. The valves, oil, filter-driers and seals get checked or changed, and the settings are redone for the new refrigerant. Topping off with something different skips all of that.

Will my walk-in cool as well after a retrofit?

It can, when the parts are sized for the new refrigerant and the valves are set up for it.

Older walk-in on R-404A or R-22? Call (865) 214-7334.

Source: Sporlan (Parker) Form 5-492, "System Considerations for Refrigerant Blends with Temperature Glide," from the Parker Sporlan educational literature library: https://discover.parker.com/literature-educational. Regulation details: U.S. EPA, "Phaseout of Class II Ozone-Depleting Substances," https://www.epa.gov/ods-phaseout/phaseout-class-ii-ozone-depleting-substances; "Technology Transitions HFC Restrictions by Sector," https://www.epa.gov/hfcs/technology-transitions-hfc-restrictions-sector; "Hydrofluorocarbons (HFCs)," https://www.epa.gov/hfcs; GreenChill "Relevant EPA Programs," https://www.epa.gov/greenchill/relevant-epa-programs.